I'm looking for a dual timer that can turn on a CO2 and turn off a fan. I wonder if anyone can recommend one. I was looking at the Sunleaves SunDial Dual Timer, but not sure if it can do it Sunleaves SunDial Dual Timer ![]()
__________________ What exactly is a Delta Bucket? Click Here GroweroftheDank's NLxBB Grow Journal Click Here No statements made in any post or message by myself should be understood to mean that I choose to participate in activities which break federal, state, or local laws. All posts are strictly fictional. | ||
| | |
| | #2 | ||
| Administrator ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() Join Date: Aug 2002
Posts: 11,728
Thanks: 6,421
Thanked 10,060 Times in 3,628 Posts
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | you need a climate controller. something with a photo sensor so that it can keep the co2 off during night cycle. i was looking at one of these a while back when i was thinking about upgrading the co2 system i have. i didnt get it, but if i do, its most likely what i would get. https://www.greenair.com/product/40.html
__________________ ![]() | ||
| | |
| The Following 4 Users Say Thank You to bobbooty For This Useful Post: |
| | #3 | ||
| Ultimate Gardener ![]() ![]() ![]() ![]() ![]() Join Date: Feb 2002 Location: 9000 plus ft---Getting Higher by the day
Posts: 5,583
Thanks: 11,205
Thanked 14,432 Times in 3,329 Posts
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
I use Control Wizard for my brain to run my co2 and fans, they run right around a bill I think. Only turns the co2 on during daylight hours, and when the fans come on, turns off the co2. Have a couple of them, and been using them for years now with great luck. Happy Co2ing Alleycat
__________________ Life is Beautiful ![]() "Time flies like an arrow, fruit flies like a banana"---Groucho Marx "I'm a man, but I can change, if I have to, I guess"---Red Green DYNAMITE (MY CAT)/(MY STRAIN)(Don't forget Pumpkin either now)And coming shortly Blueberry Posting Guidelines | ||
| | |
| The Following 3 Users Say Thank You to alleycat For This Useful Post: |
| | #4 | ||
| Master Gardener ![]() Join Date: Oct 2007
Posts: 1,866
Thanks: 3,275
Thanked 2,558 Times in 1,121 Posts
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | i bought 2 shit timers that didnt work properly, my brother (electrician) suggested that i run half the current on one timer and half on the other. hehe it works fine, although they seem to have a 18h day (says 24h on them) but that was cool, i needed stash quicker (was going abroad) so how about using 2 timers (good ones ) and synchronizing them? | ||
| | |
| | #5 | ||
| Grand Master Gardener ![]() ![]() ![]() Join Date: Jan 2002 Location: a land far far away
Posts: 3,630
Thanks: 591
Thanked 4,909 Times in 2,263 Posts
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | or make the shitty timer trip an AC relay. that should handle your load. | ||
| | |
| The Following User Says Thank You to Luke Highwalker For This Useful Post: | Tommy_Chong (10-22-2008) |
| | #6 | ||
| Novice Gardener Join Date: Jul 2008 Location: Planet Earth
Posts: 96
Thanks: 68
Thanked 176 Times in 67 Posts
![]() ![]() ![]() | Those control modules are nice, but a bit out of my price range. I only put the CO2 on 4 times a day for 15 mins. I was going to use 2 independent timers, and just have the CO2 come on when the exhaust turns off. My only concern is keeping the 2 syncronized. Maybe some sort of relay switch that would turn off the blower then the solenoid on the co2 is turned on. Maybe something like a cut-off relay switch type deal but not sure where to start on components. Any help? Maybe I should ask in an electrical website.
__________________ What exactly is a Delta Bucket? Click Here GroweroftheDank's NLxBB Grow Journal Click Here No statements made in any post or message by myself should be understood to mean that I choose to participate in activities which break federal, state, or local laws. All posts are strictly fictional. | ||
| | |
| | #7 | ||
| Ganja G33k ![]() ![]() ![]() Join Date: Aug 2007 Location: /dev/null
Posts: 3,303
Thanks: 2,550
Thanked 7,349 Times in 2,446 Posts
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Dual Outlet Analog Timer | Timers personaly I'd leave co2 on the shelf till you can afford a controller system
__________________ How to keep your hydro reservoir cold "People use the word "natural" ... What is natural to me is these botanical species which interact directly with the nervous system. What I consider artificial is 4 years at Harvard, and the Bible, and Saint Patrick's cathedral, and the sunday school teachings." - Timothy Leary | ||
| | |
| | #8 | ||
| Master Gardener ![]() Join Date: Jan 2007
Posts: 1,262
Thanks: 2,354
Thanked 2,218 Times in 736 Posts
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | i made one with this time clock 59-581-1015 is what you want (mfg # TA-4079) ... what you want to look for on them is the SPDT That stands for Single Pole Double Throw one load is off while the other is on i was going to use the one i made for when i get another 600w hps ... two rooms, one is off while the other is on so there is just one constant 600w load T_C | ||
| | |
| | #9 | ||
| Jr. Gardener Join Date: Oct 2008 Location: down south
Posts: 100
Thanks: 116
Thanked 107 Times in 57 Posts
![]() ![]() ![]() |
I bought a dual (2 PLUG INS) timer at Home Depot for $30.00 and change. Named "INTERTMATIC" # HB88RG HEAVY DUTY OUTDOOR DIGITAL TIMER iT HAS 7 PROGRAMS VERY NICE | ||
| | |
| The Following User Says Thank You to gatorman For This Useful Post: | analog (10-27-2008) |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| dual ballast | jarvis2542 | Lighting | 5 | 11-04-2007 09:59 AM |
| Dual 250 watt or dual 400 watt for 8-12 square feet?? | Zoiks | Lighting | 0 | 03-04-2005 09:06 PM |
| 800-watt dual | cat5 | Lighting | 1 | 09-26-2002 07:25 PM |
| dual ballast | CreepinTheDeers | Lighting | 4 | 04-22-2002 10:24 PM |
| New To Site? | Need Help? |